Recent reports of widespread National Security Agency spying and NSA encryption circumvention provide an eye-opener on the vulnerability of data in transit and stored online. 
Like it or not, the revelation is forcing businesses concerned with data privacy or secrecy to rethink how they can protect data from hackers and state-sponsored groups.
 While eschewing online services by bringing IT in house can solve  many data security issues, it does entail setting up dedicated  on-premises equipment. This can be intimidating for a small business,  especially given the recent focus on online services. Moreover,  resources designed to help tend to assume a medium-sized or enterprise  installation, which may not necessarily work well for setting up a small  server room or even a closet for a branch office.
With some understanding of the basics, though, setting up your own  server room need not be an arcane process. Here are some tips for  getting started.
 Rack-Mount Equipment Makes Sense
 It's not uncommon for small businesses to begin operation by stacking  server hardware and network appliances on a desk or shelf. Though such a  deployment is inexpensive, the pile of equipment invariably expands  into an unmanageable mess with the growth of the company. Exposed  equipment is also completely open to physical tampering and is a ticking  time bomb for accidents such as coffee spills, dust or even workers  tripping over wires.
 However, rack-mount equipment is designed specifically to properly  house this type of hardware. While these tend to be pricier than their  non-rack mount equivalents, it's arguable that being easier to manage  far exceeds the cost premium. In addition, shelves and drawers designed  for mounting onto the server rack are widely available; these let racks  work with non-rack mount appliances as necessary.
 There's a Server Rack for All Seasons
 Before getting the server rack, it's good to first understand its  basic characteristics. Server racks are measured in terms of rack units,  usually written as "RU" or simply "U." One rack unit equals 1.75 inches  (44.45mm) in high, with compliant equipment measured in multiples of  "U." Network switches are generally 1U to 2U, servers can range from 1U  to 4U and blade servers can be anywhere from 5U to 10U or more.
 Consider, too, the width and depth of the server rack, which is  generally accepted to be 19 inches for the former and 600mm to 1,000mm  for the latter. Some server racks come with adjustable rear brackets,  though most rack mount servers come with adjustable mounting kit that  can be used as long as there's sufficient depth for the server.
The most common commodity server rack today is probably the four-post  rack designed to hold servers and appliances 19 inches wide. A typical  full-height rack measures 42U; half-height equates to 24U. Other options  exist, including desktop variants that range from 5U to 20U. (These  measurements don't pertain to the external dimension of the rack; that  varies depending on design.) Optional caster wheels can be handy for  limited mobility.
 Two alternative for space-constrained locations are open frame racks  or small wall-mounted cabinets. Keep in mind, though, that open frame  racks may have special mounting requirements, such as being bolting to  the floor, while wall-mounted cabinets may not be suitable for loads  heavier than network switches or just a few servers.
 Isolate Servers to Reduce Noise
 Organizations without the luxury of a dedicated room for server  equipment will want to consider noise management. Whenever possible, a  small, partitioned room is worth the expense. Aside from substantially  dampening or even eliminating productivity-sapping equipment noise,  having a room for your server gear also offers the ability to secure IT  equipment against casual theft or tampering.
 In small businesses, where there's no option but to place your rack  in the corner of the room or within the IT department itself, racks with  sound-dampening properties are highly recommended. Since air vents make  complete soundproofing impossible, these racks are generally measured  by their noise-reduction properties. How well they work is a combination  of the noise generated the one's equipment and the overall  sound-reduction capabilities of the rack itself.
 Beat the Heat and Get an AC Unit (or Two)
 If all you plan to deploy is a couple of network switches and a  five-bay network attached storage (NAS) system, then you probably don't  need to worry about cooling. Pack in several more servers, a mid-sized  uninterruptible power supply and a larger NAS, though, and the heat  starts building up quickly. Needless to say, high temperatures can  dramatically shorten equipment life and often culminate in inexplicable  crashes or outages.
 It's possible to compare the thermal load of the rack with the  thermal output of your server equipment, but a common-sense approach of  measuring the temperature inside the rack is often sufficient. Keeping  your equipment cool isn't isolated to the heat dissipation capabilities  of your server rack; it's also directly affected by the ambient  temperature outside the rack. That's why installing air-conditioning  units in the server room is recommended.
One often-overlooked concern is what happens when servers remain on  after office hours. In such scenarios, you'll need a separate  air-conditioning unit that's not tied to the building's central air  unit, which is typically switched off after a certain hour. Ideally,  businesses should install two standalone units in the room, on separate  circuit breakers, for redundancy. This also allows them to be alternated  regularly for servicing.
 Proper cable management (see next section) also helps ensure proper  ventilation. Generally, it's not a good idea to cram 42 1U servers into a  full-height rack. Not only does this create cabling constraints, older  server chassis may need 1U to 2U of space between each other to ensure  adequate airflow. (Most modern rack-mount servers don't need such  spacing.)
 Managing Wires Isn't Glamorous, But It's Necessary
 Setting up a server rack is more than just twisting a few screws to  secure the equipment into place. Proper cable management can't be  overstated, as just about every piece of equipment in the rack is linked  with Ethernet cables. Intra-cabinet wiring aside, it makes sense to  terminate cable runs for Ethernet LAN points for desktop computers, IP cameras and other network appliances at the rack.
The best way to properly manage all these cables is to use an RJ45  patch panel to terminate Ethernet cable runs. The typical patch panel  installs in 1U of space and offers up to 24 ports. Using a patch panel  does require some hands-on work - stripping a cable, punching it into  the patch panel and using a wire tester tool to verify the connectivity.  (If hiring a professional is in the budget, he or she can probably get  everything installed in less than a day.)
 In addition to a patch panel, always have a bag of cable ties handy  to easily secure stray cables. Standard cable ties are "throwaway" cheap  when purchased in bulk, though releasable ones that can be reused  aren't that much more expensive.
 Label Everything - and Keep It Simple
 Finally, don't skimp on labeling and documenting your setup, even for  relatively simple deployments. What may be obvious to the employer  setting it up could be missed by a new IT staffer or a vendor contracted  to work on certain aspects of the system. Time savings aside, proper  labeling reduces the likelihood of catastrophic mistakes such as a  mission-critical system getting unplugged or restarted without adequate  warning.
 The simplest way to properly label your infrastructure? Purchase a  label printer from a hardware shop. Servers and network appliances  should be labeled with unique descriptive names and their IP addresses.  Ditto for other equipment such as keyboard, video and mouse switches,  NAS appliances, routers, data backup devices and redundant hardware.
 Detailed notes describing important procedures relating to your  on-premises hardware should be printed out and attached to the server  cabinet with tape or refrigerator magnets. These notes should important  operating instructions relating to networking, data backup or shutting  down (or starting up) the equipment in the event of a power outage.